Armored Figure 8 Aerial Cable
Specifications
Configuration |
| ||
Temperature Range | Storage and transport -40 to +60°C | Installation -20 to +60°C | Operation -40 to +60°C |
Standards | IEC 60793-1, IEC 60793-2, IEC 60794-3-20 | ||
Customer Reference | Common standard |
Dimensions
Number of fibers | 6 | |
Loose tubes x fibers | 1x6 | |
Loose tubes/Dummies | 1/0 | |
Outer diameter (W*H) | mm | (6.0±0.5)*(10.8±0.5) |
Weight | kg | 60±15% |
Note: sheath thickness not consider ripcord portion, sizes and values without tolerances are nominal values
The weight of zinc coating of uncoated wire surface shall be more than 20g/m2
Mechanical Properties
Max. tensile load | Short term: 1000N;long term:200N | ||
Crush resistance / 10 cm | Short term:1000 N;long term:200N | ||
Bending radius (installation) | 20x cable Ø | ||
Bending radius (operation) | 10x cable Ø |
See Point 6: Test Methods
Optical Fiber
Standard | ALF® ITU-T G.652D | ||
Optical | Fibre attenuation | @ 1310 nm ≤0.36 dB/km | @ 1550 nm ≤0.22 dB/km |
Mode field diameter (MFD) | 9.2 ± 0.4 µm@1310nm | ||
Zero dispersion wavelength | 1300~1324 nm | ||
Zero dispersion slope | ≤0.092 ps/nm² ∙km | ||
Polarisation mode dispersion (PMD) | ≤0.2 ps/√km | ||
Cable Cut-off wavelength | ≤1260 nm | ||
Geometric | Outer diameter | 245 ± 10 µm | |
Cladding diameter | 125 ± 1.0 µm | ||
Core/clad concentricity error | ≤0.6 µm | ||
Cladding non-circularity | ≤1.0 % | ||
Mechanical | Proof stress | ≥0.69 Gpa |
Test Methods
Test | Conditions | Acceptance criteria |
Tensile strength | Tensile strength: see Point 3 |
|
Crush resistance | Crush: see Point 3 |
|
Impact | Impact energy: 5 J |
|
Torsion | Sample length: 2 m |
|
Repeated Bend | Bending radius: 20x cable Ø |
|
Temperature cycling | -40℃→ +60℃ |
|
Water penetration | Sample length: 3 m |
|
All optical measurements at 1550 nm (G652D) or 1300 nm (OM2/OM3/OM4)
Logistics
Cable type | Length Tolerance | 4km -5% / +5% | D*d*B in cm |
GYXTC8S-6G.652D | Drum Type Dimensions Weight | Wood 95*50*75 290kg |
Dimensions including protection. Indicative values, actually delivered drum sizes and weights may deviate. Cable ends sealed with caps