Duct and direct buried optical cable 12 fibers OM2 GYXTW53-12OM2
1.
Identification | GYXTW53-12OM2 | ||
Application | Duct and direct buried optical cable | ||
Configuration |
| ||
Temperature Range | Storage and transport -10 to +70°C | Installation 0 to +70°C | Operation -10 to +70°C |
Standards | IEC 60793-1, IEC 60793-2, IEC 60794-3-10 | ||
Specification No. | GL20200825323 | ||
Customer Reference | Common standard |
Number of fibers | 12 | |
Loose tubes x fibers | 1x12 | |
Loose tubes/Dummies | 1/0 | |
Outer diameter | mm | 12.4±5% |
Weight | kg | 160±15% |
Note: sheath thickness not consider ripcord portion, sizes and values without tolerances are nominal values
Max. tensile load | Short term: 3000N | ||
Crush resistance / 10 cm | Short term:3000N | ||
Bending radius (installation) | 20x cable Ø | ||
Bending radius (operation) | 15x cable Ø |
See Point 6: Test Methods
Standard | ITU-T OM2 TELE WEAVE - BroadTMOM2 | ||
Optical | Fibre attenuation | @ 850 nm ≤3.5 dB/km | @ 1300 nm ≤1.5 dB/km |
Standard bandwidth | ≥ 500MHz.km | ≥ 500MHz.km | |
Numerical Aperture (NA) | 0.200 ± 0.015μm | ||
Geometric | Core diameter | 50 ± 2.5 µm | |
Cladding diameter | 125 ± 1.0 µm | ||
Core/clad concentricity error | ≤1.5 µm | ||
Cladding non-circularity | ≤2.0 % | ||
Mechanical | Proof stress | ≥0.69 Gpa (100 kpsi) | |
Coating strip force | 1.3~8.9 N |
Test | Conditions | Acceptance criteria |
Tensile strength | Tensile strength: see Point 3 |
|
Crush resistance | Crush: see Point 3 |
|
Impact | Impact energy: 10 J |
|
Torsion | Sample length: 1 m |
|
Bend | Bending diameter: 20x cable Ø |
|
Repeated Bend | Bending radius: 20x cable Ø |
|
Temperature cycling | -10℃→ +70℃ |
|
Water penetration | Sample length: 3 m |
|
All optical measurements at 1550 nm (G652D) or 1300 nm (OM2/OM3/OM4)
Cable type | Length Tolerance | 2km -2% / +2% | D*d*B in cm |
GYXTW53-12OM2 | Drum Type Dimensions Weight | Wooden 115*50*75cm 390kg |
Dimensions including protection. Indicative values, actually delivered drum sizes and weights may deviate. Cable ends sealed with caps