Technical data
No. of cable | 6 | 12 | 24 | |
Fiber Model | G.652D | |||
Design(StrengthMember+Tube&Filler) | 1+5 | |||
Central Strength Member | Material | Steel Wire | ||
Diameter(±0.05)mm | 1.4 | |||
Loose Tube | Material | PBT | ||
Diameter(±0.06)mm | 1.65 | |||
Thickness(±0.03)mm | 0.25 | |||
Filler Rope | Material | LDPE | ||
Diameter(±0.06)mm | 1.65 | |||
Water Blocking layer(Material) | Flooding Compound | |||
Armoring | Material | Steel Strip | ||
Thickness(±0.03)mm | 0.20 | |||
Outer Sheath | Material | MDPE | ||
Thickness(±0.2)mm | 1.6 | |||
Cable Diameter(±0.2)mm | 8.9 | |||
Cable Wetght(±5.0)kg/km | 82 | |||
Min. bending radius | Without Tension | 10.0×Cable-φ | ||
Under Maximum Tension | 20.0×Cable-φ | |||
Temperature range (℃) |
Installation | -20~+60 | ||
Transport&Storage | -40~+70 | |||
Operation | -40~+70 |
The properties of single mode optical fiber (ITU-T Rec. G.652.D)
Item | Specification |
Fiber type | Single mode |
Fiber material | Doped silica |
Attenuation coefficient @ 1310 nm @ 1383 nm @ 1550 nm @ 1625 nm |
£ 0.35 dB/km £ 0.32 dB/km £ 0.21 dB/km £ 0.24 dB/km |
Point discontinuity | £ 0.05 dB |
Cable cut-off wavelength | £ 1260 nm |
Zero-dispersion wavelength | 1300 ~ 1324 nm |
Zero-dispersion slope | £ 0.092 ps/(nm2.km) |
Chromatic dispersion @ 1288 ~ 1339 nm @ 1271 ~ 1360 nm @ 1550 nm @ 1625 nm |
£3.5 ps/(nm. km) £5.3 ps/(nm. km) £18 ps/(nm. km) £22 ps/(nm. km) |
PMDQ (Quadrature average*) | £0.2 ps/km1/2 |
Mode field diameter @ 1310 nm | 9.2±0.4 um |
Core / Clad concentricity error | £ 0.5 um |
Cladding diameter | 125.0 ± 0.7 um |
Cladding non-circularity | £1.0% |
Primary coating diameter | 245 ± 10 um |
Proof test level | 100 kpsi (=0.69 Gpa), 1% |
Application
NO. | Item | Requirement | |
1 | Allowable Tensile Strength | Short Term | 1500 N |
Long Term | 600 N | ||
2 | Allowable Crush Resistance | Short Term | 1000 (N/100mm) |
Long Term | 300 (N/100mm) |
Main mechanical & environmental performance test
Item | Test Method | Acceptance Condition |
Tensile Strength IEC 794-1-2-E1 |
- Load: Short term tension - Length of cable: about 50m |
- Fiber strain £ 0.33% - Loss change £ 0.1 dB @1550 nm - No fiber break and no sheath damage. |
Crush Test IEC 60794-1-2-E3 |
- Load: Short term crush - Load time: 1min |
- Loss change £ 0.05dB@1550nm - No fiber break and no sheath damage. |
Impact Test IEC 60794-1-2-E4 |
- Points of impact: 3 - Times of per point: 1 - Impact energy: 5J |
- Loss change £ 0.1dB@1550nm - No fiber break and no sheath damage. |
Temperature Cycling Test YD/T901-2001-4.4.4.1 |
- Temperature step: +20oC→-40oC→+70oC →+20oC - Time per each step: 12 hrs - Number of cycle: 2 |
- Loss change £ 0.05 dB/km@1550 nm - No fiber break and no sheath damage. |
Sheath marking
The optical fiber drop cable shall have sequentially numbered length marking at intervals of approximately 1 meter. The starting number of ordering length for any coil shall begin whit zero meter. The accuracy of the measurement of lenth marking shall be held within the limits of ±1%.
a) Manufacturer’s name
b) Type of wire
c) Year and month of manufacture
d) Length marking each meter along the wire