| Identification | OFC-12~48 G.657A2-DiC(W)-S3 | ||
| Configuration |
|
||
| Temperature range |
Storage and transport |
Installation |
Operation |
| Standards | IEC 60793-1, IEC 60793-2, IEC 60794-3-10, EN 50290-2-24 | ||
| Customer Reference | Common standard | ||
2 Dimensions
| Fiber Counts | 12 | 24 | 48 |
| No. of Loose tube | 12 | 24 | 48 |
| Fiber No. per module | 1 | ||
| Outer diameter | 11.0±0.5mm | 12.4±0.5mm | 15.0±0.5mm |
3 Mechanical Properties
| Fiber counts | 12 | 24 | 48 |
| Tensile load | 1000N | ||
| Crush resistance | 2000N/10cm | ||
| Min. bending radius | Without tension 10D | ||
4 Marking
![]()
5 Optical Fiber
| Standard | ITU-T G.657A2 | ||
| Optical |
Fibre attenuation |
@1310 nm |
@1550 nm |
| Zero Dispersion Wavelength | 1300~1324 nm | ||
| Zero Dispersion Slope | ≤0.092 ps/nm2∙km | ||
|
Macro bending Loss |
|
||
| Mode Field Diameter @1310 nm | (8.6~9.2)±0.4 μm | ||
| Geometric | Cladding Diameter | 125±1 μm | |
| Cladding non circularity | ≤ 1.0% | ||
| Core/clad concentricity error | ≤ 0.5μm | ||
| Mechanical | Proof stress | ≥ 0.69 GPa | |
6 Test Methods
| Test | Conditions | Acceptance criteria |
|
Tension Loading |
Tensile strength: see Point 3 |
- Attenuation change reversible - No damage |
|
Crush/Compression |
Crush: see Point 3 |
- Attenuation change reversible - No damage |
|
Impact Resistance |
Impact energy: 5 J |
- Attenuation change reversible - No damage |
|
Repeated Bending |
Bending radius: 20D, |
- Attenuation change reversible - No damage |
|
Torsion/Twist |
Sample length: 2 m |
- Attenuation change reversible - No damage |
|
Bend |
Bending radius: 10D |
- Attenuation change reversible - No damage |
|
Temperature cycling |
-20°C ~ +70°C |
- Change of attenuation ≤ 0.10 dB/km at 1550nm - No damage |
|
Water penetration |
Sample length: 3 m, water column height: 1 m |
- No water leakage from the loose trbe |
All optical measurements at 1550 nm
Contact Us at Any Time