| Cable Type | GCYFXTY-XB1.3(MTE + Cable diameter) | |||
| MTE2.0 | MTE2.3 | MTE2.5 | MTE2.8 | |
| Fiber Count | 2~4 | 6~12 | 2~12 | 14~24 | 
| Thickness of HDPE sheath | Nominal value:0.20mm, Average value:0.15mm | |||
| Nominal Overall Diameter | 2.0±0.1mm | 2.3±0.1mm | 2.5±0.1mm | 2.8±0.1mm | 
| Weight | 4.0 kg/km | 5.0 kg/km | 6.0 kg/km | 7.0kg/km | 
| Cable Fibre Attenuation (single mode) | 0.35dB/km max @1310nm 0.22dB/km max @1550nm | |||
| Max. Tensile Strength | 40N | 50N | 60N | 60N | 
| Max. Crushing force | 600N/100mm | |||
| Min. Bending radius -Static / Dynamic | 10 / 20 outer Φ | |||
| Temperature | Storage -30~+50℃;Installation-10~+40℃;Operation-20~+50℃ | |||
| Cable service life (estimate value) | 25 years | |||
Blowing performance
| Blowing Tool | Typical blowing length | ||
| PLUMETTAZ:PR-140, MiniJet-400 etc. Air pressure : 13bar | Fibres Count | Duct type 3.5/5.0mm | Duct type 5.5/7.0mm | 
| 2~12 fibres | 800m | 1500m | |
| 14~24 fibres | / | 1500m | |
Mechanic performance
| Item | Testing Method | Testing Results | Specified Value | |
| Tension performance | IEC 60794-1-21-E1 | Optical fibre strain | Additional attenuation | Max. Tensile Strength = Short term Allowable tension ≈2×(Long term Allowable Tension) | 
| Short term:≤0.3% Long term:≤0.1% | Short term: 
 Long term: | |||
| Crush | IEC 60794-1-21-E3 | Short term: Long term: The outer sheath has no visible crack. | Short term crushing force =600 N Long term crushing force =300 N | |
| Repeated bending | IEC 60794-1-21-E6 | After test,  The outer sheath has no visible crack. | R=20 outer Φ | |
| Bending load =15N | ||||
| Bending times =25 | ||||
| Torsion | IEC 60794-1-21-E7 | After test,  The outer sheath has no visible crack. | Torsion angle=±180º | |
| Torsion load =15N | ||||
| Torsion times =5 | ||||
| Cable bend | IEC 60794-1-21-E11A | After test, The optical fibre can’t be broken; The outer sheath has no visible crack. | R=20 outer Φ 10Turns Cycles times =5 | |
| All optical testing proceeded at 1550 nm | ||||
Environment performance
| Item | Testing Method | Testing Results | ||
| Temperature cycling | IEC 60794-1-22-F1 | Allowable additional attenuation (1550nm) | ||
| G.652B | G.652D | G.657 | ||
|  ≤0.10 dB/km,  reversible; | ||||
| Water penetration | IEC 60794-1-22-F5B | Water column: 1m, 3m cable, Period:24 hours No water leak through the open end of cable | ||
| Filling compound flow | IEC 60794-1-22-F16 | 70℃,Period:24 hours No compound flow from the cable | ||
Other Index
                             
Sheath color: Green
Sheath Marking
The outer sheath is marked at intervals of 1 meter as follows:
ABC MINI number and type of fibre MTE Cable diameter [MM-YYYY] =length marking in meter=
Example: ABC MINI 24 G652D MTE2.8 [04- 2014] =1888m=
Delivery Lengths
Standard delivery lengths are 2km, 4km, 6km with a tolerance of -1%~+3%.
| Fibre Count | Drum length (m) | Drum Size Φ×W (mm) | Packing Size L×W×H (mm) | Weight (Gross) (kg) | 
| 2~12 Fibres φ2.0-2.5 | 2000 | Φ450×370 | 480×370×645 | 27 | 
| 4000 | Φ500×370 | 530×370×695 | 39 | |
| 6000 | Φ550×370 | 580×370×745 | 51 | |
| 14~24 Fibres φ2.8 | 2000 | Φ500×370 | 530×370×695 | 31 | 
| 4000 | Φ550×370 | 580×370×745 | 46 | |
 
Wooden or plywood drums with protection.