Send Message
Dawnergy Technologies(Shanghai) Co., Ltd.
Email Peter.bi@dawnergy.com TEL: 86-21-67877780
Home > Products > Fiber Optic Management System >
48 Core Dome Type Fiber Optic Splice Closure
  • 48 Core Dome Type Fiber Optic Splice Closure

48 Core Dome Type Fiber Optic Splice Closure

Place of Origin CHINA
Brand Name dawnergy
Certification CE
Model Number DA-FOSC-DM48-P-D013-1
Product Details
Product:
Fiber Optic Splice Closure DA-FOSC-DM96-P-D002-1 48cores
Material:
PC
Application:
FTTH FTTB FTTx NETWORK
Installation:
Pole/Wall
Sealing:
Mechnical Connector
Capacity Of FOSC:
6-48 Fiber Cores
Capacity Of Each Tray:
12 Fiber Cores And 24 Fiber Cores
Cable Port:
4 Round Holes
Dimension:
288mm×178mm
High Light: 

48 Cores Fiber Optic Splice Closure

,

dawnergy Fiber Optic Splice Closures

,

48 Cores Weatherproof Fiber Enclosures

Payment & Shipping Terms
Minimum Order Quantity
100
Price
14.2USD
Payment Terms
T/T
Supply Ability
500 per day
Product Description

PC DOME Type 48 Cores Fiber Optic Splice Closure

Scope of application

The scope of application is: aerial, underground, wall-mounting, duct-mounting and handhole- mounting. The ambient temperature ranges from –40℃ to +65℃.

 

 

Basic structure and configuration

      Dimension and capacity

Outside dimension (Height x Diameter) 288mm×178mm
Weight (excluding outside box) 1800g—1910g
Number of inlet/outlet ports 4 pieces
Diameter of fiber cable Φ8mm~Φ16 mm
Capacity of FOSC Bunchy: 4-48 (cores)

     Main components

No. Name of components Quantity Usage Remarks
1 FOSC cover 1 piece Protecting fiber cable splices in whole

Height x Diameter

208mm x 132mm

2 Fiber optic splice tray (FOST) Max. 4 trays (bunchy) Fixing heat shrinkable protective sleeve and holding fibers Suitable for: Bunchy:4,6,8,12,(cores)
3 Fiber holding tray 1 pcs Holding fibers with protective coat  
4 Base 1set Fixing internal and external structure  
5 Plastic hoop 1 set Fixing between FOSC cover and base  
6 Seal fitting 1 piece Sealing between FOSC cover and base  
7 Pressure testing valve 1 set After inject air, it is used for pressure testing and sealing testing Configuration as per requirement
8 Earthing deriving device 1 set Deriving metal parts of fiber cables in FOSC for earthing connection Configuration as per requirement

 

    Main accessories and special tools

No. Name of accessories Quantity Usage Remarks
1 Heat shrinkable protective sleeve   Protecting fiber splices Configuration as per capacity
2 Nylon tie   Fixing fiber with protective coat Configuration as per capacity
3 Earthing wire 1 piece Putting through between earthing devices To put through as per actual requirement
4 Abrasive cloth 1 piece Scratching fiber cables  
5 Labeling paper 1 piece Labeling fibers  
6 Special wrench 2 pieces Installing and tightening nut of reinforced core and nut (plastic) of inlet/outlet tube  
7 Measuring paper 1 piece To measure perimeter, of which its diameter is enlarged with seal tape To measure perimeter with the corresponding measuring paper
8 Seal tape 1 ring Enlarging diameter of fiber cable which fits in with gasket ring. Configuration as per specification
9 Insulation tape 1 ring Enlarging diameter of fiber cable for easy fixing  
10 Metal hoop 1 set For wall mounting and pole hugging  
11

Buffer tube

 

decided by customers Hitched to fibers and fixed with FOST, managing buffer. Configuration as per requirement
12 Desiccant 1 bag Put into FOSC before sealing for desiccating air  

 

Necessary tools for installation

      Supplementary materials (to be provided by operator)

Name of materials Usage
Scotch tape Labeling, temporarily fixing
Ethyl alcohol Cleaning
Gauze Cleaning

 

 

 

     Special tools (to be provided by operator)

Name of tools Usage
Fiber cutter Cutting off fiber cable
Fiber stripper Strip off protective coat of fiber cable
Combo tools Assembling FOSC

 

     Universal tools(to be provided by operator)

Name of tools Usage and specification
Band tape Measuring fiber cable
Pipe cutter Cutting fiber cable
Electrical cutter Take off protective coat of fiber cable
Combination pliers Cutting off reinforced core
Screwdriver Crossing/Paralleling screwdriver
Scissor  
Waterproof cover Waterproof, dustproof
Metal wrench Tightening nut of reinforced core

 

    Splicing and testing instruments (to be provided by operator)

Name of instruments Usage and specification
Fusion Splicing Machine Fiber splicing
OT DR Splicing testing
Provisional splicing tools Provisional testing

 

 

Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves.

 

Fiber Optic Splice Closures (FOSC) inspecting and testing items

 

Inspecting item Technical Requirements Inspecting type
Routine test (Before leaving factory) Type test
Package Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. full

 

 

 

At least 3 sets sampled each time

 

Appearance Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual.
Sign There is a clear sign on the housing, such as name and model of the product, etc.
Fiber storage device The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers.

 

 

 

At least 3 sets sampled each time

 

Electrical jointing device Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing
Sealing performance After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure.
Re-sealing performance After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure.
Pull Bearing pull is ≧ 800N at axle orientation, there should be no breakage on the housing.
Punching Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing
Impact Bearing impact energy of 16N•m, 3 times of impacts there should be not breakage on the housing
Bending The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±450 for 10 circles, there should be no breakage on the housing

 

 

 

 

 
Torsion

Bearing torsion 50N•m, 10 circle at torsion angle±900,

There should be no breakage on the housing.

Temperature circle Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40℃~+65℃, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is ≦5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles.
Voltage resistance strength After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes.
Isolating resistance After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be ≧ 2×104MΩ.

 

 

 

Contact Us at Any Time

86-21-67877780
1st Floor, A5 Building, NO.3655 SixianRd, Songjiang District, Shanghai 201614 China
Send your inquiry directly to us