Tensile Load 200N G657A2 LSZH Anti UV Om2 Fiber Cable

Basic Information
Place of Origin: CHINA
Brand Name: DAWNERGY
Certification: CE/TELCORDIA
Model Number: GJFXZY-6OM2
Minimum Order Quantity: 100KM
Packaging Details: Wooden DRUM
Delivery Time: 10-20 work days
Payment Terms: T/T, L/C, D/A, D/P
Supply Ability: 10,000KM PER DAY
Product: Indoor/outdoor Duct Optical Cable Outer Sheath: LSZH, Orange, Anti-UV
Application: Indoor/outdoor Duct No. Of Fiber Per Tube: 6
Strength Member: Glass Yarn And Water Blocking Yarn
High Light:

Anti UV Om2 Fiber Cable

,

LSZH Om2 Fiber Cable

,

DAWNERGY Aerial Optical Fiber Cable

Indoor optical cable 48 Fibers G657A2 GJFZY-48G.657A2
 
1.

IdentificationGJFXZY-6OM2
ApplicationIndoor/outdoor duct optical cable
Configuration
  • Loose tube with max 6 fibers per tube, filled with thixotropic compound
  • Strength member:Glass yarn and water blocking yarn
  • Outer sheath: LSZH, Orange, anti-UV
Temperature Range

Storage and transport

-20 to +60°C

Installation

-20 to +60°C

Operation

-20 to +60°C

StandardsIEC 60793-1, IEC 60793-2, IEC 60794-3-10
Specification No.GL20200825323
Customer ReferenceCommon standard
  1. Dimensions
Number of fibers 6
Loose tubes x fibers 1x6
Loose tubes/Dummies 1/0
Outer diametermm6.0±0.5
Weightkg45±15%

Note: sheath thickness not consider ripcord portion, sizes and values without tolerances are nominal values

  1. Mechanical Properties
Max. tensile load Short term: 600N;long term:200N 
Crush resistance / 10 cm Short term:1000 N;long term:200N
Bending radius (installation) 20x cable Ø
Bending radius (operation) 10x cable Ø

See Point 6: Test Methods

  1. Marking

Tensile Load 200N G657A2 LSZH Anti UV Om2 Fiber Cable 0

  1. Optical Fiber
StandardITU-T OM2 TELE WEAVE - BroadTMOM2
Optical

Fibre attenuation
.. cabled

@ 850 nm

≤3.5 dB/km

@ 1300 nm

≤1.5 dB/km

Standard bandwidth≥ 500MHz.km≥ 500MHz.km
Numerical Aperture (NA)0.200 ± 0.015μm
GeometricCore diameter50 ± 2.5 µm
Cladding diameter125 ± 1.0 µm
Core/clad concentricity error≤1.5 µm
Cladding non-circularity≤2.0 %
MechanicalProof stress≥0.69 Gpa (100 kpsi)
Coating strip force1.3~8.9 N

 

  1. Test Methods
TestConditionsAcceptance criteria

Tensile strength
IEC 60794-1-2 E1

Tensile strength: see Point 3
Sample length: ≥ 50 m, Duration: 1 min

  • Fiber strain≤0.6%
  • △α reversible
  • No damage

Crush resistance
IEC 60794-1-2 E3

Crush: see Point 3
Test duration: 1 min, number of test: 3

  • △α reversible
  • No damage

Impact
IEC 60794-1-2 E4

Impact energy: 5 J
R = 300 mm, number of places/tests: 3

  • △α reversible
  • No damage

Torsion
IEC 60794-1-2 E7

Sample length: 2 m
± 180°, 5 cycles

  • △α reversible
  • No damage

Repeated Bend
IEC 60794-1-2 E6

Bending radius: 20x cable Ø
25 cycles

  • No damage

Temperature cycling
IEC 60794-1-2 F1

-20℃→ +60℃
12 hours at each step, 2 cycles

  • △α≤0.2 dB/km and reversible
  • No damage

Water penetration
IEC 60794-1-2 F5

Sample length: 3 m
Water column height: 1 m
Test duration: 24 h

  • No water leakage

All optical measurements at 1550 nm (G652D) or 1300 nm (OM2/OM3/OM4)

  1. Logistics
Cable type

Length

Tolerance

4km

-5% / +5%

Tensile Load 200N G657A2 LSZH Anti UV Om2 Fiber Cable 1

D*d*B in cm

GJFXZY-6OM2

Drum Type

Dimensions

Weight

Plywood suitable for indoor storage

75*35*57cm

200kg

Dimensions including protection. Indicative values, actually delivered drum sizes and weights may deviate. Cable ends sealed with caps
 

Contact Details
Peter Bi

Phone Number : 0086 21 67606111

WhatsApp : +008615002176701