IEC 60793-1 LSZH Anti UV 12 Fibers OM4 Optic Fiber Cable

Basic Information
Place of Origin: CHINA
Brand Name: DAWNERGY
Certification: CE/TELCORDIA
Model Number: GJFXZY-12OM4
Minimum Order Quantity: 100KM
Packaging Details: Wooden DRUM
Delivery Time: 10-20 work days
Payment Terms: T/T, L/C, D/A, D/P
Supply Ability: 10,000KM PER DAY
Product: Indoor/outdoor Duct Optical Cable 12 Fibers OM4 Outer Sheath: LSZH, Violet, Anti-UV
Application: Indoor/outdoor Duct No. Of Fiber Per Tube: 12
Strength Member: Glass Yarn And Water Blocking Yarn
High Light:

OM4 Optic Fiber Cable

,

DAWNERGY LSZH Optic Fiber Cable

,

DAWNERGY Optic Fiber Cable

 

Indoor/outdoor duct optical cable 12 fibers OM4

 

1.

Identification GJFXZY-12OM4
Application Indoor/outdoor duct optical cable
Configuration
  • Loose tube with max 12 fibers per tube, filled with thixotropic compound
  • Strength member:Glass yarn and water blocking yarn
  • Outer sheath: LSZH, Violet, anti-UV
Temperature Range

Storage and transport

-20 to +60°C

Installation

-20 to +60°C

Operation

-20 to +60°C

Standards IEC 60793-1, IEC 60793-2, IEC 60794-3-10
Specification No. GL20200825323
Customer Reference Common standard
  1. Dimensions
Number of fibers   12
Loose tubes x fibers   1x12
Loose tubes/Dummies   1/0
Outer diameter mm 6.0±0.5
Weight kg 45±15%

Note: sheath thickness not consider ripcord portion, sizes and values without tolerances are nominal values

  1. Mechanical Properties
Max. tensile load   Short term: 600N;long term:200N  
Crush resistance / 10 cm   Short term:1000 N;long term:200N
Bending radius (installation)   20x cable Ø
Bending radius (operation)   10x cable Ø

See Point 6: Test Methods

  1. Marking

IEC 60793-1 LSZH Anti UV 12 Fibers OM4 Optic Fiber Cable 0

 

  1. Optical Fiber
Standard ITU-T OM4 TELE WEAVE - BroadTMOM4
Optical

Fibre attenuation

.. cabled

@ 850 nm

≤3.0 dB/km

@ 1300 nm

≤0.8 dB/km

Bandwidth (overfilled) ≥ 3500MHz.km ≥ 500MHz.km
Bandwidth (EMB) @ 850 nm ≥ 4700MHz.km
Numerical aperture (NA) 0.200±0.015μm
Point discontinuity ≤0.1 dB
Attenuation uniformity ≤0.1 dB/km
Attenuation coefficient difference for bi-directional measurement ≤0.1 dB/km
Geometric Core diameter 50 ± 2.5 µm
Cladding diameter 125 ± 1.0 µm
Coating diameter (uncolored) 245 ± 10 µm
Core/clad concentricity error ≤1.5 µm
Core non-circularity ≤5.0 %
Cladding non-circularity ≤2.0 %
Cladding/coating concentricity error ≤12.0 µm
Mechanical Proof stress ≥0.69 Gpa (100 kpsi)
Coating strip force 1.0~8.9 N

 

  1. Test Methods
Test Conditions Acceptance criteria

Tensile strength

IEC 60794-1-2 E1

Tensile strength: see Point 3

Sample length: ≥ 50 m, Duration: 1 min

  • Fiber strain≤0.6%
  • △α reversible
  • No damage

Crush resistance

IEC 60794-1-2 E3

Crush: see Point 3

Test duration: 1 min, number of test: 3

  • △α reversible
  • No damage

Impact

IEC 60794-1-2 E4

Impact energy: 5 J

R = 300 mm, number of places/tests: 3

  • △α reversible
  • No damage

Torsion

IEC 60794-1-2 E7

Sample length: 2 m

± 180°, 5 cycles

  • △α reversible
  • No damage

Repeated Bend

IEC 60794-1-2 E6

Bending radius: 20x cable Ø

25 cycles

  • No damage

Temperature cycling

IEC 60794-1-2 F1

-20℃→ +60℃

12 hours at each step, 2 cycles

  • △α≤0.2 dB/km and reversible
  • No damage

Water penetration

IEC 60794-1-2 F5

Sample length: 3 m

Water column height: 1 m

Test duration: 24 h

  • No water leakage

All optical measurements at 1550 nm (G652D) or 1300 nm (OM2/OM3/OM4)

  1. Logistics
Cable type

Length

Tolerance

4km

-5% / +5%

IEC 60793-1 LSZH Anti UV 12 Fibers OM4 Optic Fiber Cable 1

D*d*B in cm

GJFXZY-12OM4

Drum Type

Dimensions

Weight

Plywood suitable for indoor storage

75*35*57cm

200kg

Dimensions including protection. Indicative values, actually delivered drum sizes and weights may deviate. Cable ends sealed with caps

Contact Details
Peter Bi

Phone Number : 0086 21 67606111

WhatsApp : +008615002176701